Search results for "Limiting current density"
showing 3 items of 3 documents
Experiments and modelling for determining the Limiting Current Density in Electrodialysis units
2018
In the present work, in order to explore such issues on the LCD identification, we performed in-situ measurements with ED units, assessing the influence of operating conditions and validating a purposely implemented process simulator, which was then used for further investigation
Effect of membrane profiles on the limiting current density in electrodialysis
2019
In the present work, we experimenrtally investigated the effect of different membrane profiles on the LCD, testing also different operating conditions.
Determination of limiting current density and current efficiency in electrodialysis units
2018
Abstract A crucial parameter for the design and operation of electrodialysis (ED) units is the limiting current density (LCD). This is often identified with the diffusion-limited current density, which corresponds to the complete solute depletion in the layer adjacent to the membrane. Current-voltage curves obtained from measurements with electrodes in contact with the solution (i.e. without membranes) are consistent with this interpretation and exhibit a horizontal plateau identifying LCD. However, real ED systems show more complex behaviours, with a reduced-slope tract instead of a plateau and a third region in which the current increases more markedly (overlimiting current). The phenomen…